Understanding a machine’s life-cycle is key to leveraging MAAS effectively. Everything that happens to a machine under MAAS control conforms to a specific life-cycle. All MAAS machines are in a named state, or in transition between states. Most of these transitions are user-controlled. Only the “failure” state is reached under the direction of MAAS, when a user’s request for certain state changes can’t be successfully completed.

Machine states

In general, the various states and transitions can be summarised in a diagram:

image

The central state flow at the bottom of the diagram is the “standard” life-cycle. If all goes well, you won’t have to deviate much from this flow:

Once deployed, there are a couple of minor state changes you can effect without releasing the machine:

Note that these minor state changes are not shown in the diagram above. There are also some exceptional states you can command:

There is one more state that a machine can get into: “failed”. This state is entered when commissioning, allocation, or deployment are not successful. Getting out of a failed state means figuring out what went wrong, correcting it, and retrying the failed operation. For example, when a machine fails, you can try and commission it again, hopefully after you’ve found the bug in your custom commissioning script that’s causing it to fail (for instance).

Now that we have a solid overview of the life-cycle, let’s break down some of these states and transitions in greater detail.

Enlistment

MAAS is built to manage machines, including the operating systems on those machines. Enlistment and commissioning are features that make it easier to start managing a machine – as long as that machine has been configured to netboot. Enlistment enables users to simply connect a machine, configure the firmware properly, and power it on so that MAAS can find it and add it.

Enlistment happens when MAAS starts; it reaches out on connected subnets to locate any nodes – that is, devices and machines – that reside on those subnets. MAAS finds a machine that’s configured to netboot (e.g., via PXE), boots that machine into Ubuntu, and then sends cloud-init user data which runs standard (i.e., built-in) commissioning scripts. The machine actually adds itself over the MAAS API, and then requests permission to send commissioning data.

Since MAAS doesn’t know whether you might intend to actually include these discovered machines in your cloud configuration, it won’t automatically take them over, but it will read them to get an idea how they’re set up. MAAS then presents these machines to you with a MAAS state of “New.” This allows you to examine them and decide whether or not you want MAAS to manage them.

When you configure a machine to netboot – and turn it on while connected to the network – MAAS will enlist it, giving it a status of “New.” You can also add a machine manually. In either case, the next step is commissioning, which boots the machine into an ephemeral Ubuntu kernel so that resource information can be gathered. You can also run custom commissioning scripts to meet your specific needs.

Enlistment details

When MAAS enlists a machine, it first contacts the DHCP server, so that the machine can be assigned an IP address. An IP address is necessary to download a kernel and initrd via TFTP, since these functions can’t accept domain names. Once the machine has a bootable kernel, MAAS boots it:

image

Next, initrd mounts a Squashfs image, ephemerally via HTTP, so that cloud-init can execute:

image

Finally, cloud-init runs enlistment and setup scripts:

image

The enlistment scripts send information about the machine to the region API server, including the architecture, MAC address and other details. The API server, in turn, stores these details in the database. This information-gathering process is known as automatic discovery or network discovery.

Typically, the next step will be to commission the machine. As an alternative to enlistment, an administrator can add a machine manually. Typically this is done when enlistment doesn’t work for some reason. Note that when you manually add a machine, MAAS automatically commissions the machine as soon as you’ve added it.

After the commissioning process, MAAS places the machine in the ‘Ready’ state. ‘Ready’ is a holding state for machines that are commissioned, waiting to be deployed when needed.

MAAS runs built-in commissioning scripts during the enlistment phase. When you commission a machine, any customised commissioning scripts you add will have access to data collected during enlistment. Follow the link above for more information about commissioning and commission scripts.

BMC enlistment

For IPMI machines, you only need to provide IPMI credentials. MAAS automatically discovers the machine and runs enlistment configuration by matching the BMC address. For non-IPMI machines, you must specify a non-PXE MAC address. MAAS automatically discovers the machine and runs enlistment configuration by matching the non-PXE MAC address.

Adding machines

There are two ways to add a machine to MAAS:

  1. If you place the machine on a connected network, and the machine is configured to netboot, MAAS will automatically enlist it.

  2. If you add a machine manually, MAAS will automatically commission it. There are also ways to turn off this automatic commissioning, should you desire to do so.

MAAS typically adds a machine via a combination of DHCP, TFTP, and PXE. By now, you should have enabled MAAS to automatically add devices and machines to your environment. This unattended method of adding machines is called enlistment.

Configuring a computer to boot over PXE is done via its BIOS, often referred to as “netboot” or “network boot”. Normally, when you add a machine manually, MAAS will immediately attempt to commission the machine. Note that you will need to configure the underlying machine to netboot, or commissioning will fail. MAAS cannot handle this configuration for you. While the correct method for configuring network boot depends heavily on your server, there are two common elements:

  1. The network card on your server must be able to support PXE, i.e., your NIC – whether independent or integrated on a motherboard – must have a boot PROM that supports network booting. You’ll need to consult the documentation for the machine in question to determine this. Note that in MAAS versions before 2.5, you are required to provide the MAC address of the PXE interface when adding a new machine manually.

  2. You usually have to interrupt the boot process and enter the BIOS/UEFI menu to configure the network card’s PXE stack. Again, you may need to consult your machine’s documentation to pin down this step.

Additional steps will vary widely by machine type and architecture.

Regardless of how MAAS adds a machine, there are no special requirements for the underlying machine itself, other than being able to netboot. In particular, there is no need to install an operating system on it.

Cloning (3.1++)

MAAS v3.1 and higher provides the ability to quickly clone or copy configuration from one machine to one or more machines, via the MAAS UI, providing convenient access to an existing API feature.. This is a step towards machine profile templating work.

Creating a machine profile is a repetitive task. Based on the responses to our survey – and multiple forum posts, we have learned that most users create multiple machines of the same configuration in batches. Some users create a machine profile template and loop them through the API, while some create a script to interface with the CLI. However, there is no easy way to do this in the UI except by going through each machine and configuring them individually.

MAAS API already has the cloning functionality, but it was never exposed in the UI. Hence, users may not know that this API feature exists, nor is there any current documentation about how to use this feature. Although the current cloning API feature does not solve all machine profile templating problems, it is a great place for us to start moving in the direction of machine templates.

Faithful copies

As a MAAS user – API or UI – you may want to copy the configuration of a given machine and apply it to multiple existing machines. Assuming that at least one machine is already set to the desired configuration, you should be able to apply these same settings to a list of destination machines. This means that a user should be able to:

What to copy?

As a MAAS user, you will likely want to select whether storage, network, or both configurations should be cloned. The cloning API allows users to choose interfaces and storage separately. Thus, this new feature should allow the user to:

Restrictions

In order for cloning to succeed, a few restrictions must be met:

Adding live machines (3.1++)

In general, when adding a machine to MAAS, it network boots the machine into an ephemeral environment to collect hardware information about the machine. While this is not a destructive action, it doesn’t work if you have machines that are already running a workload.

For one, you might not be able to disrupt the workload in order to network boot it. But also, the machine would be marked as Ready, which is incorrect.

When adding a machine, you may specify that the machine is already deployed. In that case, it won’t be going through the normal commissioning process and will be marked as being deployed.

Such machines lack hardware information. In order to update the information, a script is provided to run a subset of the commissioning scripts and send them back to MAAS.

Because already-deployed machines were not deployed by MAAS, most of the standard MAAS commands will not affect the machine and may, at times, return some odd results. This is not errant behaviour; the goal of enlisting deployed machines is to avoid disturbing their workload.